(+91) 82706 58519

Customer Care Number

Tiruchirapalli, IN

Address location

TEC BEAT EP

CORROSION PROTECTIVE COATING SYSTEM

Epoxy-based corrosion protective coating system for steel and concrete surfaces. Can be applied over structural steel and exposed concrete surfaces.

KEY BENEFITS AND FEATURES

USAGE

DIRECTIONS FOR USE

Surface Preparation

Proper surface preparation is the key to any successful Epoxy application. The surface to be coated should be free of dust, laitance, oils or other contaminants. Water jetting or brisk srubbing should be adapted to remove surface contaminants. For old Surfaces with heavy oil contamination, detergent washing with mechanical scrubbing should be followed by thorough water washing. For new concrete surfaces ample time should be allowed after completion of curing. The moisture content before application of the Coating should not exceed 5%. TecR Beat EP can be applied directly to mild steel and concrete surfaces. Mild Steel Surfaces should be free of rust and scales while applying Tec Beat EP. Ideally Grit Blasting would be advised. Priming coat is not always required. In specific cased of highly porous Concrete surfaces a priming coat of TecR Nova Primer EP may be applied prior to application of TecR Beat EP.

Mixing

TecR Beat EP is a two component system. For consistent results mix the entire contents of Part-B – Hardener to PartA- Base and mix gently for about 3 minutes preferably with a slow speed drill fitted with a stainless steel mixing paddle. The resulting homogenous mix must be of a uniform shade. Care should be taken to maintain a clean environment in the mixing area to ensure that the mix is free of any contamination. Ease out air bubbles in the mix before application. Do not thin.

Application

The mix should then be applied over the prepared surface quickly ensuring that the entire mix is used up well within the pot life. The application should be done with a brush and finished with a roller. Ensure that a neat film is formed without blow holes, air bubbles or fisheyes. The second coat of TecR Beat EP should be applied when the first coat has reached tack free stage. Avoid application at temperatures above 35°c or below 15°c.

Post Application

The coated area should be allowed to set at room temperature for a minimum period of 7 days.

Technical Data

Physical StatePart- A- Liquid Part-B- Liquid
ColourSilver Grey and Sage Green
FinishGlossy
Percentage of Solids40%
Pot Life at 30°C1 hour Minutes.
Touch Dry4 Hours.
Over Coating5-6 Hours
Initial Setting15 Hours
Final Setting7 Days
Chemical ResistanceResistant to a wide range of Acids, Alkali’s and solvents. Separate Chemical Resistance Chart is available on request.
 Coverage5-6 M 2/Kg of Mix/Coat (Coverage will vary depending on porosity of the substrate)

PRECAUTIONS

In cases where application involves prolonged inhalation of solvent vapors, adequate ventilation should be ensured before commencing the application job. Direct contact with skin or eyes should be avoided. Use of gloves, goggles and other protective gear is mandatory. In case of accidental eye contact thorough water washing is advised. This should be followed up with professional medical assistance. Neither the individual components nor the mix should be swallowed. Both components of TecR Beat EP are flammable and adequate precautions should be taken at the site.

Storage and Shelf life

  As TecR Beat EP is moisture sensitive. Store it at dry conditions. Store under cover, out of direct sunlight and protect from extremes of temperature. Shelf life is 12 months when stored as above. Failure to comply with there commended storage conditions may result in premature deterioration of the product or packaging.

CLEANING

Tools and equipments should be cleaned with TecR Nova SOL-Tool Cleaner when the mix is in uncured state. Cured mix can only be removed mechanically

Packaging

Available in 1Kg & 6Kg

OTHER PRODUCTS

Techny manufactures lot more range of other products for construction and repair applications. They include admixtures for concrete, mortars, block making etc, waterproof and damp proof coating systems, Repair and rehabilitations products, Grouts and Anchors, Protective, Decorative and Corrosion prevention coatings, Epoxy Flooring systems, Industrial flooring systems and Tiling aids. For more details refer Separate Product brochures.

Every reasonable precaution is taken in the manufacture of the Techny products to ensure that they comply with high standards of quality. The recommendations and properties of the products are based upon what is believed to be the most reliable information available and are not intended as recommendations which infringe other patents. Although all Techny products are subject to rigid quality tests, no specific guarantee can be given, because results depend not only on quality but also on other factors beyond our control. We therefore welcome consultation in the event of doubt about application performance etc but do not accept any liability either directly or indirectly arising from the use of the products whether used as per its specifications or advice or otherwise. All transactions shall be subject to our terms of sale, delivery and payment. The leaflet supercedes the previous one and any new issue may take place without notice to supercede this edition as and when it becomes necessary.

TECHNICAL DATA SHEET