TEC BEAT ZR

REINFORCEMENT COATING-EPOXY ZINC RICH

Epoxy-Zinc Rich coating system for exposed reinforcement in concrete repairs. Can also be used for the protection of re-bars in highly corrosive environments. Highly recommended for use on Re-bars in RCC in coastal conditions.

KEY BENEFITS AND FEATURES

USAGE

DIRECTIONS FOR USE

Surface Preparation

Proper surface preparation is the key to any successful Epoxy application. The surface to be coated should be free of dust, laitance, oils or other contaminants. Corroded steel should be free of scales and corrosion deposits. Steel should be cleaned to a bright color before application. Ideally Grit Blasting would be advised. In case corrosion has occurred due to the presence of chlorides high pressure water washing is recommended immediately after grit blasting.

Mixing

TecR Beat ZR is a two component system. For consistent results mix the entire contents of Part-B Hardner to Part A Base and mix gently for about 3 minutes preferably with a slow speed drill fitted with a stainless steel mixing paddle. The resulting homogenous mix must be of a uniform grey shade. Care should be taken to maintain a clean environment in the mixing area to ensure that the mix is free of any contamination. Ease out air bubbles in the mix before application. Do not thin.

Application

Application of TecR Beat ZR must commence within 3 hours of surface preparation for best results. The mix should then be applied over the prepared surface quickly ensuring that the entire mix is used up well within the pot of life. The application should be done by brush ensuring an unbroken coat. A second coat of TecR Beat ZR is recommended to ensure a break free film. The second coat should be applied when the first coat is tack free dry (usually in about 1 hour). Avoid application at temperatures above 35°c or below 15°c.

Post Application : The primed surfaces should not be left exposed to the ambient conditions for longer than necessary before  overcoating. Typically TecR Beat ZR will protect steel under clean interior exposed conditions for a period of several months. In moderate exterior conditions, a maximum interval of 14 days will be endured but in industrial and/or marine environments this interval should be reduced to the practical minimum. In concrete repair, application of the repair material should proceed  immediately after the TecR Beat ZR coating is tack-free dry (usually about one hour).

Technical Data

Physical StatePart- A- Liquid Part-B- Liquid
ColourGrey
FinishMild Gloss
Specific Gravity1.75
Pot Life at 30°C30-45 Minutes.
Touch Dry60-90 Minutes.
Over Coating90-120 Minutes.
Coverage, for One coat on normal surface4-5 SqM/Kg of Mix/Coat.

PRECAUTIONS

In cases where application involves prolonged inhalation of solvent vapors, adequate ventilation should be ensured before commencing the application job. Direct contact with skin or eyes should be avoided. Use of gloves, goggles and other protective gear is mandatory. In case of accident eye contact thorough water washing is advised. This should be followed up with professional medical assistance. Neither the individual components nor the mix should be swallowed.

Storage and Shelf life

 As TecR Beat ZR is moisture sensitive. Store it at dry conditions. Store under cover, out of direct sunlight and protect from extremes of temperature. Shelf life is 12 months when stored as above. Failure to comply with there commended storage conditions may result in premature deterioration of the product or packaging.

CLEANING

Tools and equipments should be cleaned with TecR Nova SOL-Tool Cleaner when the mix is in uncured state.Cured mix can only be removed mechanically.

Packaging

Available in 1Kg & 6Kg

OTHER PRODUCTS

Techny manufactures lot more range of other products for construction and repair applications. They include admixtures for concrete, mortars, block making etc, waterproof and damp proof coating systems, Repair and rehabilitations products, Grouts and Anchors, Protective, Decorative and Corrosion prevention coatings, Epoxy Flooring systems, Industrial flooring systems and Tiling aids. For more details refer Separate Product brochures.

Every reasonable precaution is taken in the manufacture of the Techny products to ensure that they comply with high standards of quality. The recommendations and properties of the products are based upon what is believed to be the most reliable information available and are not intended as recommendations which infringe other patents. Although all Techny products are subject to rigid quality tests, no specific guarantee can be given, because results depend not only on quality but also on other factors beyond our control. We therefore welcome consultation in the event of doubt about application performance etc but do not accept any liability either directly or indirectly arising from the use of the products whether used as per its specifications or advice or otherwise. All transactions shall be subject to our terms of sale, delivery and payment. The leaflet supercedes the previous one and any new issue may take place without notice to supercede this edition as and when it becomes necessary.

TECHNICAL DATA SHEET
REVISED – February, 2010