THERMAL INSULATION TILES

Heat insulation tiles to be laid as an alternative to weather course tile, practically removing surki concrete and reducing the weight load over the roof area.

KEY BENEFITS AND FEATURES

USAGE

DIRECTIONS FOR USE

SURFACE PREPARATION

NEW SURFACE

The surface should be sound, free from dirt, oils and greases. In case if any concrete curing membranes has been used it has to be removed by wire brush thoroughly to avoid debonding.

OLD SURFACE

If the concrete has been casted and used for a while, check for cracks and if anything is found it has to be filled properly. Please read our Technical booklet for suggestions or talk to TECHNY Technical cell.

INSTALLATION

A slope of 1:100 has to be formed with TECR COOLLITEor using grano mix with 1:4:8 using 6mm downgraded chips maintaining an average thickness of 16 – 18 mm at the centre of the surface. Install the tiles with TECR BOND 25 or CM 1:5 and press the tiles gently to remove the entrapped air below the tile to avoid vacuum formation. Pointing shall be done with TECR TILE 12 – COOL. For skirting purpose, each tile must be cut into two and the edges chamfered using diamond cutting machine. The tile should be embedded in the parapet wall at the brick level and finished off with proper plastering. It is recommended not to use soft and porous materials as substrate. The compaction and air voids in these materials can cause cracks in the future.

POST APPLICATION

Wipe of the excess grout before hardening.

PROPERTIES

Physical StateSolid (Tile)
Foot traffic ratingResidential to moderate commercial
ColorWhite
Thermal Conductivity0.6 to 0.7 w/mk
Albedo (Solar reflectance)0.70
Solar reflection Index (SRI) 90.1  
Water Absorption 4.9%  
Size 1’X 1’ 

OTHER PRODUCTS

Every reasonable precaution is taken in the manufacture of the Techny products to ensure that they comply with high standards of quality. The recommendations and properties of the products are based upon what is believed to be the most reliable information available and are not intended as recommendations which infringe other patents. Although all Techny products are subject to rigid quality tests, no specific guarantee can be given, because results depend not only on quality but also on other factors beyond our control. We therefore welcome consultation in the event of doubt about application performance etc but do not accept any liability either directly or indirectly arising from the use of the products whether used as per its specifications or advice or otherwise. All transactions shall be subject to our terms of sale, delivery and payment. The leaflet supercedes the previous one and any new issue may take place without notice to supercede this edition as and when it becomes necessary.

TECHNICAL DATA SHEET
REVISED SEPTEMBER 2015